Contactor, 3p+2N/O+2N/C, 200kW/400V/AC3 | ||
Part no. | DILM400-S/22(220-240V50/60HZ) | |
Catalog No. | 274196 | |
Eaton Catalog No. | XTCS400M22B | |
EL-Nummer (Norway) | 4110263 |
General | |||
Standards |
IEC/EN 60947, VDE 0660, UL, CSA | ||
Lifespan, mechanical |
|||
AC operated |
Operations | x 106 | 7 |
Operating frequency, mechanical |
|||
AC operated |
Operations/h | 2000 | |
Climatic proofing |
Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 |
||
Ambient temperature |
|||
Open |
°C | -40 - +60 | |
Enclosed |
°C | - 40 - + 40 | |
Storage |
°C | - 40 - + 80 | |
Mounting position |
![]() ![]() |
||
Mechanical shock resistance (IEC/EN 60068-2-27) |
|||
Half-sinusoidal shock, 10 ms |
|||
Main contacts |
|||
N/O contact |
g | 10 | |
Auxiliary contacts |
|||
N/O contact |
g | 10 | |
N/C contact |
g | 8 | |
Degree of Protection |
IP00 | ||
Protection against direct contact when actuated from front (EN 50274) |
Finger and back-of-hand proof with terminal shroud or terminal block | ||
Weight |
|||
AC operated |
kg | 8.42 | |
DC operated |
kg | 8.42 | |
Weight |
kg | 8.42 | |
Terminal capacity main cable |
|||
Flexible with cable lug |
mm2 | 50 - 240 | |
Stranded with cable lug |
mm2 | 70 - 240 | |
Solid or stranded |
AWG | 2/0 - 500 MCM | |
Flat conductor |
Lamellenzahl x Breite x Dicke | mm |
Fixing with flat cable terminal or cable terminal blocks See terminal capacity for cable terminal blocks |
Busbar |
Width | mm | 25 |
Main cable connection screw/bolt |
M10 | ||
Tightening torque |
Nm | 24 | |
Terminal capacity control circuit cables |
|||
Solid |
mm2 |
1 x (0.75 - 2.5) 2 x (0.75 - 2.5) |
|
Flexible with ferrule |
mm2 |
1 x (0.75 - 2.5) 2 x (0.75 - 2.5) |
|
Solid or stranded |
AWG | 18 - 14 | |
Control circuit cable connection screw/bolt |
M3.5 | ||
Tightening torque |
Nm | 1.2 | |
Tool |
|||
Main cable |
|||
Width across flats |
mm | 16 | |
Control circuit cables |
|||
Pozidriv screwdriver |
Size | 2 | |
Main conducting paths | |||
Rated impulse withstand voltage |
Uimp | V AC | 8000 |
Overvoltage category/pollution degree |
III/3 | ||
Rated insulation voltage |
Ui | V AC | 1000 |
Rated operational voltage |
Ue | V AC | 1000 |
Safe isolation to EN 61140 |
|||
between coil and contacts |
V AC | 500 | |
between the contacts |
V AC | 500 | |
Making capacity (p.f. to IEC/EN 60947) |
A | 5500 | |
Breaking capacity |
|||
220 V 230 V |
A | 5000 | |
380 V 400 V |
A | 5000 | |
500 V |
A | 5000 | |
660 V 690 V |
A | 5000 | |
1000 V |
A | 950 | |
Component lifespan |
|||
AC1: See → Engineering, characteristic curves AC3: See → Engineering, characteristic curves AC4: See → Engineering, characteristic curves |
|||
Short-circuit rating |
|||
Short-circuit protection maximum fuse |
|||
Type “2” coordination |
|||
400 V |
gG/gL 500 V | A | 500 |
690 V |
gG/gL 690 V | A | 500 |
1000 V |
gG/gL 1000 V | A | 200 |
Type “1” coordination |
|||
400 V |
gG/gL 500 V | A | 630 |
690 V |
gG/gL 690 V | A | 630 |
1000 V |
gG/gL 1000 V | A | 250 |
AC | |||
AC-1 |
|||
Rated operational current |
|||
Conventional free air thermal current, 3 pole, 50 - 60 Hz |
|||
Open |
|||
at 40 °C |
Ith =Ie | A | 612 |
at 50 °C |
Ith =Ie | A | 548 |
at 55 °C |
Ith =Ie | A | 522 |
at 60 °C |
Ith =Ie | A | 500 |
enclosed |
Ith | A | 450 |
Notes |
At maximum permissible ambient air temperature. | ||
Conventional free air thermal current, 1 pole |
|||
Note |
at maximum permissible ambient air temperature | ||
open |
Ith | A | 1250 |
enclosed |
Ith | A | 1125 |
AC-3 |
|||
Rated operational current |
|||
Open, 3-pole: 50 – 60 Hz |
|||
220 V 230 V |
Ie | A | 400 |
240 V |
Ie | A | 400 |
380 V 400 V |
Ie | A | 400 |
415 V |
Ie | A | 400 |
440V |
Ie | A | 400 |
500 V |
Ie | A | 400 |
660 V 690 V |
Ie | A | 325 |
1000 V |
Ie | A | 95 |
Motor rating |
P | kWh | |
220 V 230 V |
P | kW | 125 |
240V |
P | kW | 132 |
380 V 400 V |
P | kW | 212 |
415 V |
P | kW | 232 |
440 V |
P | kW | 250 |
500 V |
P | kW | 280 |
660 V 690 V |
P | kW | 300 |
1000 V |
P | kW | 132 |
AC-4 |
|||
Rated operational current |
|||
Open, 3-pole: 50 – 60 Hz |
|||
220 V 230 V |
Ie | A | 296 |
240 V |
Ie | A | 296 |
380 V 400 V |
Ie | A | 296 |
415 V |
Ie | A | 296 |
440 V |
Ie | A | 296 |
500 V |
Ie | A | 296 |
660 V 690 V |
Ie | A | 260 |
1000 V |
Ie | A | 95 |
Motor rating |
P | kWh | |
220 V 230 V |
P | kW | 92 |
240 V |
P | kW | 100 |
380 V 400 V |
P | kW | 160 |
415 V |
P | kW | 176 |
440 V |
P | kW | 186 |
500 V |
P | kW | 210 |
660 V 690 V |
P | kW | 240 |
1000 V |
P | kW | 132 |
Condensor operation | |||
Individual compensation, rated operational current Ie of three-phase capacitors |
|||
Open |
|||
up to 525 V |
A | 307 | |
690 V |
A | 177 | |
Max. inrush current peak |
x Ie | 30 | |
Component lifespan |
Operations | x 106 | 0.1 |
Max. operating frequency |
Ops/h | 200 | |
DC | |||
Rated operational current, open |
|||
DC-1 |
|||
Notes |
see DILDC300/DILDC600 or on request | ||
Current heat loss | |||
3 pole, at Ith (60°) |
W | 58 | |
Current heat loss at Ie to AC-3/400 V |
W | 37 | |
Magnet systems | |||
Voltage tolerance |
|||
US |
220 - 240 V 50/60 Hz | ||
AC operated |
Pick-up | x US | 0.85 x US min - 1.1 x US max |
AC operated |
Drop-out | x US | 0.2 x US min - 0.4 x US max |
Power consumption of the coil in a cold state and 1.0 x US |
|||
Note on power consumption |
Control transformer with uk ≦ 10% | ||
Pull-in power |
Pick-up | VA | 715 |
Pull-in power |
Pick-up | W | 645 |
Sealing power |
Sealing | VA | 6.8 |
Sealing power |
Sealing | W | 4 |
Duty factor |
% DF | 100 | |
Changeover time at 100 % US (recommended value) |
|||
Main contacts |
|||
Closing delay |
ms | 55 | |
Opening delay |
ms | 50 | |
Behaviour in marginal and transitional conditions |
|||
Sealing |
|||
Voltage interruptions |
|||
(0 … 0.2 x Uc min) ≦ 10 ms |
Time is bridged successfully | ||
(0 … 0.2 x Uc min) > 10 ms |
Drop-out of the contactor | ||
Voltage drops |
|||
(0.2 … 0.6 x Uc min) ≦ 12 ms |
Time is bridged successfully | ||
(0.2 … 0.6 x Uc min) > 12 ms |
Drop-out of the contactor | ||
(0.6 … 0.7 x Uc min) |
Contactor remains switched on | ||
Excess voltage |
|||
(1.15 … 1.3 x Uc max) |
Contactor remains switched on | ||
Pick-up phase |
|||
(0 … 0.7 x Uc min) |
Contactor does not switch on | ||
(0.7 x Uc min … 1.15 x Uc max) |
Contactor switches on with certainty | ||
Admissible transitional contact resistance
(of the external control circuit device when actuating A11) |
mΩ | ≦ 500 | |
Electromagnetic compatibility (EMC) | |||
Electromagnetic compatibility |
This product is designed for operation in industrial environments (environment A). Its use in residential environments (environment 1) may cause radio-frequency interference, requiring additional noise suppression measures. | ||
Rating data for approved types | |||
Switching capacity |
|||
Maximum motor rating |
|||
Three-phase |
|||
200 V 208 V |
HP | 125 | |
230 V 240 V |
HP | 150 | |
460 V 480 V |
HP | 300 | |
575 V 600 V |
HP | 400 | |
General use |
A | 450 | |
Auxiliary contacts |
|||
Pilot Duty |
|||
AC operated |
A600 | ||
DC operated |
P300 | ||
General Use |
|||
AC |
V | 600 | |
AC |
A | 15 | |
DC |
V | 250 | |
DC |
A | 1 | |
Short Circuit Current Rating |
SCCR | ||
Basic Rating |
|||
SCCR |
kA | 30 | |
max. Fuse |
A | 800 | |
max. CB |
A | 600 | |
480 V High Fault |
|||
SCCR (fuse) |
kA | 30/100 | |
max. Fuse |
A | 800/600 Class J | |
SCCR (CB) |
kA | 100 | |
max. CB |
A | 600 | |
600 V High Fault |
|||
SCCR (fuse) |
kA | 30/100 | |
max. Fuse |
A | 800/600 Class J | |
SCCR (CB) |
kA | 30 | |
max. CB |
A | 600 | |
Special Purpose Ratings |
|||
Definite Purpose Ratings (100,000 cycles acc. to UL 1995) |
|||
LRA 480V 60Hz 3phase |
A | 3300 | |
FLA 480V 60Hz 3phase |
A | 550 | |
LRA 600V 60Hz 3phase |
A | 3120 | |
FLA 600V 60Hz 3phase |
A | 420 |
Product Standards | IEC/EN 60947-4-1; UL 60947-4-1; CSA - C22.2 No. 60947-4-1-14; CE marking | ||
UL File No. | E29096 | ||
UL Category Control No. | NLDX | ||
CSA File No. | 012528 | ||
CSA Class No. | 3211-04 | ||
North America Certification | UL listed, CSA certified | ||
Specially designed for North America | No |
![]() |
|||
on the side: 2 x DILM820-XHI11(V)-SI; 2 x DILM820-XHI11-SA | |||
![]() |
|||
Normal switching duty Normal AC induction motor Operating characteristics Switch on: from stop Switch off: during run Electrical characteristics: Switch on: up to 6 x Rated motor current Switch off: up to 1 x Rated motor current Utility category 100 % AC-3 Typical Applications Compressors Lifts Mixers Pumps Escalators Agitators fan Conveyor belts Centrifuges Hinged flaps Bucket-elevator Air-conditioning systems General drives for manufacturing and processing machines |
|||
![]() |
|||
Extreme switching duty Squirrel-cage motor Operating characteristics Inching, plugging, reversing Electrical characteristics Make: up to 6 x rated motor current Break: up to 6 x rated motor current Utilization category 100 % AC-4 Typical applications Printing presses Wire-drawing machines Centrifuges Special drives for manufacturing and processing machines |
|||
![]() |
|||
Switching conditions for 3 pole, non-motor loads Operating characteristics Non inductive and slightly inductive loads Electrical characteristics Switch on: 1 x rated operational current Switch off: 1 x rated operational current Utilization category 100 % AC-1 Typical examples of application Electric heat |
|||
![]() |
|||
Short-time loading, 3-pole Time interval between two loading cycles: 15 minutes |
IL03406002Z (AWA2100-1639) Contactors >170 A |
|||||||
|
|||||||
IL03406005Z (AWA2100-2212) Contactors >170 A |
|||||||
|
|||||||
![]() |
UL/CSA: Approved rating data | ||||||
![]() |
UL/CSA: UL/CSA: Short Circuit Current Rating (SCCR) | ||||||
![]() |
Switchgear of Power Factor Correction Systems | ||||||
![]() |
X-Start - Modern Switching Installations Efficiently Fitted and Wired Securely | ||||||
![]() |
Mirror Contacts for Highly-Reliable Information Relating to Safety-Related Control Functions | ||||||
![]() |
Effect of the Cabel Capacitance of Long Control Cables on the Actuation of Contactors | ||||||
![]() |
Motor starters and "Special Purpose Ratings" for the North American market | ||||||
![]() |
Switchgear for Luminaires | ||||||
![]() |
Standard Compliant and Functionally Safe Engineering Design with Mechanical Auxiliary Contacts | ||||||
![]() |
The Interaction of Contactors with PLCs | ||||||
![]() |
Busbar Component Adapters for modern Industrial control panels |